21 lau_config_setdisplaygroup (0x01a7), Lau_config_setdisplaygroup (0x01a7) – Beijer Electronics SCOM RBC EN User Manual

Page 51

Advertising
background image

Command Reference

Beijer Electronics, MAEN993

51

5.6.21LAU_CONFIG_SETDISPLAYGROUP

(0x01A7)

Device Group

Besides the standard addressing scheme, where the lowest four address bits in field
ADR are used to address a total count of 16 devices in a network, the Beijer Electron-
ics RBCs use also the upper four bits, which indicates a group of devices in a network
(max. 15 groups). The device grouping is activated, if the software configured device
address is used (the DIL switch settings are ignored). This function stores the new
group the device belongs to.

Supported since Firmware Version

LAUER RBC: 0.0.0.1

Command Stream

Response Message (Acknowledge)

Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.

Maximum Lr for this Command
9

Note:

The changes made by this command will become active only after a restart of the de-

vice. This avoids loosing the connection to the device during configuration.

0

1

2

3

4

5

6

7...9

10

0x07

ADR

0x4C

0x41

0x55

0x03

ICHKH 0x01 0xA7 Param

ICHKD

Param

Value:

0 ... 14

Type:

Byte

Length:

1

Description: New display group to be stored

0

1

2

3

4

5

6

7

8

0x06

ADR

0x4C

0x41

0x55

0x01

ICHKH

Ret

ICHKD

Ret

Value:

0 ... 14

Type:

Byte

Length:

1

Description: Stored display group

Advertising