Command Reference

Beijer Electronics, MAEN993

29

5.6.7 LAU_CONFIG_GETPOTMODE (0x0113)

POT Mode

Returns the local backlight level control configuration. If the local backlight control
is enabled, the backlight level can be changed using the front panel buttons and by
remote control (via RS232, RS485 or USB interface). If the local backlight control
is disabled, the backlight level cannot be changed using the front panel buttons. It
can be still changed by any remote control option. The configured backlight level
control can be temporarily overridden by the SCOM command “POT”.

Supported since Firmware Version
LAUER RBC: 0.0.0.1

Command Stream

Response Message (Acknowledge)

Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.

Maximum Lr for this Command
9

Example
Get the local backlight level control configuration of the device at address 0.7 (group
0, address 7):

According to the data returned by the device at address 0.7 (group 0, address 7), the
local backlight level control is enabled:

0

1

2

3

4

5

6

7...8

9

0x07

ADR

0x4C

0x41

0x55

0x02

ICHKH 0x01

0x13

ICHKD

0

1

2

3

4

5

6

7

8

0x06

ADR

0x4C

0x41

0x55

0x01

ICHKH

Ret

ICHKD

Ret

Value:

0x00: Local backlight level control enabled
0x01: Local backlight level control disabled

Type:

Byte

Length:

1

Description: Local backlight level control mode

0

1

2

3

4

5

6

7...8

9

0x07

0x07

0x4C

0x41

0x55

0x02

0x0D

0x01

0x13

0xEB

0

1

2

3

4

5

6

7

8

0x06

0x07

0x4C

0x41

0x55

0x01

0x0F

0x00

0xFF