5.6.16 LAU_CONFIG_SETCOMSERMODE

(0x0110)

SCOM Serial Interface Mode

The serial interface mode indicates the physical type of the serial interface used for
the SCOM communication. Available modes are RS232 and RS485. RS232 allows
a point-to-point communication, i.e. computer and Beijer Electronics RBC or Beijer
Electronics RBC and Beijer Electronics RBC. With RS485, many devices can be at-
tached to the same physical line and can be controlled by one or more computers,
allowing a kind of networking. Limitation is given only by the physical characteristics
of the RS485 bus.

This command sets the software configured serial interface mode. It is used, if the
device is configured to override the DIL switch settings.

Supported since Firmware Version
LAUER RBC: 0.0.0.1

Command Stream

Response Message (Acknowledge)

Note:

The changes made by this command will become active only after a restart of the de-

vice. This avoids loosing the connection to the device during configuration.

0

1

2

3

4

5

6

7...9

10

0x07

ADR

0x4C

0x41

0x55

0x03

ICHKH 0x01

0x10

Param ICHKD

Param

Value:

0x00: The serial interface will be configured as RS232
0x01: The serial interface will be configured as RS485

Type:

Byte

Length:

1

Description: Software configured serial interface mode used for SCOM

communication

0

1

2

3

4

5

6

7

8

0x06

ADR

0x4C

0x41

0x55

0x01

ICHKH

Ret

ICHKD

Ret

Value:

0x00: The serial interface is configured as RS232
0x01: The serial interface is configured as RS485

Type:

Byte

Length:

1

Description: Indicates which interface is used if the software settings are

used