Beijer Electronics BFI-P2 V1.21 User Manual

Page 44

Advertising
background image

User Guide Revision 1.12 

 

www.beijerelectronics.com 

44

8.5. Parameter Group 0 – Monitoring Parameters (Read Only) 

Par 

Description 

Units 

P0‐01 

Analog Input 1 Applied Signal Level 

Displays the signal level applied to analog input 1 (Terminal 6) after scaling and offsets have been applied. 

P0‐02 

Analog Input 2 Applied Signal Level 

Displays the signal level applied to analog input 2 (Terminal 10) after scaling and offsets have been applied. 

P0‐03 

Digital Input Status 

‐ 

Displays the status of the drive inputs, starting with the left hand side digit = Digital Input 1 etc. 

P0‐04 

Pre Ramp Speed Controller Reference 

Hz 

Displays the set point reference input applied to the drive internal speed controller 

P0‐05 

Torque Controller Reference 

Displays the set point reference input applied to the drive internal torque controller 

P0‐06 

Digital Speed Reference (Motorised Pot) 

Hz 

Displays the value of the drive internal Motorised Pot (used for keypad) speed reference 

P0‐07 

Fieldbus Communication Speed Reference 

Hz 

Displays the setpoint being received by the drive from the currently active Fieldbus interface. 

P0‐08 

PID Reference (Setpoint) 

Displays the setpoint input to the PID controller. 

P0‐09 

PID Feedback Level 

Displays the Feedback input signal to the PID controller 

P0‐10 

PID Controller Output 

Displays the output level of the PID controller 

P0‐11 

Applied Motor Voltage 

Displays the instantaneous output voltage from the drive to the motor 

P0‐12 

Output Torque 

Displays the instantaneous output torque level produced by the motor 

P0‐13 

Trip History Log 

‐ 

Displays the last four fault codes for the drive. Refer to section Error! Reference source not found. for further information 

P0‐14 

Motor Magnetising Current (Id) 

Displays the motor magnetising Current, providing an auto tune has been successfully completed. 

P0‐15 

Motor Rotor Current (Iq) 

Displays the motor Rotor (torque producing) current, providing an auto tune has been successfully completed. 

P0‐16 

DC Bus Voltage Ripple Level 

Displays the level of ripple present on the DC Bus Voltage. This parameter is used by the Drive for various internal protection and 
monitoring functions. 

P0‐17 

Motor Stator resistance (Rs) 

Ω 

Displays the measured motor stator resistance, providing an auto tune has been successfully completed. 

P0‐18 

Motor Stator Inductance (Ls) 

Displays the measured motor stator inductance, providing an auto tune has been successfully completed. 

P0‐19 

Motor Rotor Resistance (Rr) 

Ohms 

Displays the measured motor rotor resistance, providing an auto tune has been successfully completed. 

P0‐20 

DC Bus Voltage 

Displays the instantaneous DC Bus Voltage internally within the drive 

P0‐21 

Drive Temperature 

°C 

Displays the Instantaneous Heatsink Temperature measured by the drive 

P0‐22 

Time Remaining to next service 

Displays the number of hours remaining on the service time counter before the next service is due. 

P0‐23 

Operating Time Accumulated With Heatsink Temperature Above 80°C 

HH:MM:SS 

Displays the amount of time in hours and minutes that the Drive has operated for during its lifetime with a heatsink temperature in 
excess of 80°C. This parameter is used by the Drive for various internal protection and monitoring functions. 

P0‐24 

Operating Time Accumulated With Ambient Temperature Above 80°C 

HH:MM:SS 

Displays the amount of time in hours and minutes that the Drive has operated for during its lifetime with an ambient temperature in 
excess of 80°C. This parameter is used by the Drive for various internal protection and monitoring functions. 

P0‐25 

Rotor Speed (Estimated or Measured) 

‐ 

In Vector control mode, this parameter displays either the estimated rotor speed of the motor, if no encoder feedback is present, or 
the measured rotor speed if an optional Encoder Feedback Interface Option is fitted. 

Advertising