Derating information – Beijer Electronics BFI-P2 V1.21 User Manual

Page 51

Advertising
background image

User Guide Revision 1.121 

 

www.beijerelectronics.com 

51 

 
 

10.4. Derating Information 

Derating of the drive maximum continuous output current capacity is require when 

Operating at ambient temperature in excess of 40°C / 104°F 

Operating at Altitude in excess of 1000m/ 3281 ft 

Operation with Effective Switching Frequency higher than the minimum setting 

The following derating factors should be applied when operating drives outside of these conditions 

10.4.1. Derating for Ambient Temperature 

Enclosure Type 

Maximum Temperature 

Without Derating 

Derate by 

Maximum Permissable 

IP20 

50°C / 122°F 

N/A 

50°C 

IP40 

40°C / 104°F 

N/A 

40°C 

IP55 

40°C / 104°F 

1.5% per °C (1.8°F) 

50°C 

IP66 

40°C / 104°F 

2.5% per °C (1.8°F) 

50°C 

10.4.2. Derating for Altitude 

Enclosure Type 

Maximum Altitude 

Without Derating 

Derate by 

Maximum Permssable 

(UL Approved) 

Maximum Permssable 

(Non‐UL Approved) 

IP20 

1000m / 3281ft 

1% per 100m / 328 ft 

2000m / 6562 ft 

4000m / 13123 ft 

IP40 

1000m / 3281ft 

1% per 100m / 328 ft 

2000m / 6562 ft 

4000m / 13123 ft 

IP55 

1000m / 3281ft 

1% per 100m / 328 ft 

2000m / 6562 ft 

4000m / 13123 ft 

IP66 

1000m / 3281ft 

1% per 100m / 328 ft 

2000m / 6562 ft 

4000m / 13123 ft 

10.4.3. Derating for Swicthing Frequency 

 

Switching Frequency (Where available) 

Enclosure Type 

4kHz 

8kHz 

12kHz 

16kHz 

24kHz 

32kHz 

IP20 

N/A 

N/A 

20% 

30% 

40% 

50% 

IP40 

N/A 

TBC 

TBC 

TBC 

TBC 

TBC 

IP55 

N/A 

10% 

10% 

15% 

25% 

N/A 

IP66 

N/A 

10% 

25% 

35% 

50% 

50% 

 

10.4.4. Example of applying Derating Factors 

A 4kW, IP66 drive is to be used at an altitude of 2000 metres above sea level, with 12kHz switching frequency and 45°C ambient temperature. 
From the table above, we can see that the rated current of the drive is 9.5 Amps at 40°C, 
Firstly, apply the switching frequency derating, 12kHz, 25% derating 
9.5 Amps x 75% = 7.1 Amps 
Now, apply the derating for higher ambient temperature, 2.5% per °C above 40°C = 5 x 2.5% = 12.5% 
7.1 Amps x 87.5% = 6.2 Amps 
Now apply the derating for altitude above 1000 metres, 1% per 100m above 1000m = 10 x 1% = 10% 
7.9 Amps x 90% = 5.5 Amps continuous current available. 
If the required motor current exceeds this level, it will be necessary to either 

Reduce the switching frequency selected 

Use a higher power rated drive and repeat the calculation to ensure sufficient output current is available. 

Advertising