7750 SR OS Router Configuration Guide

Page 427

Monitor Commands

filter

Syntax

filter ip ip-filter-id entry entry-id [interval seconds] [repeat repeat] [absolute | rate]

Context

monitor

Description

This command monitors the counters associated with the IP filter policy.

Parameters

ip-filter-id — The IP filter policy ID.

Values

1 — 65535

entry-id — Specifies that only the counters associated with the specified filter policy entry will be

monitored.

Values

1 — 65535

interval — Configures the interval for each display in seconds.

Default

5 seconds

Values

3 — 60

repeat repeat — Configures how many times the command is repeated.

Default

10

Values

1 — 999

absolute — When the absolute keyword is specified, the raw statistics are displayed, without pro-
cessing. No calculations are performed on the delta or rate statistics.

rate — When the rate keyword is specified, the rate-per-second for each statistic is displayed instead

of the delta.

filter (ipv6)

Syntax

filter ipv6 ipv6-filter-id entry entry-id [interval seconds] [repeat repeat] [absolute | rate]

Context

monitor

Description

This command monitors the counters associated with the IPv6 filter policy.

Parameters

ipv6-filter-id — The IP filter policy ID.

Values

1 — 65535

entry-id — Specifies that only the counters associated with the specified filter policy entry will be

moniitored.

Values

1 — 65535

interval — Configures the interval for each display in seconds.