Configuring printouts, Error commands – RADWAG PUE C/31H/Z Indicator User Manual

Page 63

Advertising
background image

- 63 -

Stability character

[space] if stable
[?] if not stable
[^] if an indication over the range
[v] if fan indication below the range

sign

[space] for positive values or
[-] for negative values

mass

9 characters justified to the right

unit

3 characters justified to the left

command

3 characters justified to the left


The frame format sent by the indicator in case of setting <P2.Prnt>
to Cntb:

1 2 3

4

5

6 7-15 16 17 18 19 20 21

S U I

stability

space sign mass space

unit

CR

LF



18.7. Configuring printouts

General information

If some information included are redundant or not sufficient and there
is a necessity of changes one can design their own protocol format in
EDYTOR WAG computer program. This piece of software is accessible
in: http://www.radwag.com



19. ERROR COMMANDS

Err2

- Value beyond the zero range

Err3

- Value beyond the tare range

Err4

- Calibration mass or start mass beyond the acceptable

range (

±1% for weight, ±10 for start mass)

Err5

- Mass of a single piece lower than the scale division

Err8

- Exceeded the time for tarring, zeroing, start mass

adjustment or span adjustment

Advertising