Brocade Communications Systems 415 User Manual

Page 159

Advertising
background image

Brocade Adapters Administrator’s Guide

145

53-1001583-01

ioc

B

ioc

Enables or disables the I/O Controller (IOC), which refers to the combination of port and the
firmware controlling it.

The port can be identified using the adapter index, the port index, the port world wide name or the
port name.

Synopsis

bcu ioc --stats <port_id>

bcu ioc --statsclr <port_id>

bcu ioc --enable <port_id>

bcu ioc --disable <port_id>

bcu ioc --query <ioc_id>

bcu ioc --intr <port_id> <-coalesce | -c> {on|off} [<Latency><Delay>]

Description

The IOC commands allow you to set the interrupt attributes for the port.

CAUTION

Disabling the IOC is a destructive operation.

Operands

--stats

Displays the IOC level statistics on the specified port.

port_id

Specifies the ID of the port for which you want to display information.

--statsclr

Clears the IOC level statistics on the specified port.

port_id

Specifies the ID of the port for which you want to clear statistical information.

--enable

Enables the IO Controller (IOC). If the IOC is already enabled, the command is
ignored.

port_id

Specifies the port of the IO Controller (IOC) you want to enable.

--disable

Caution: Disabling the IOC is a destructive operation. Disables the port of the
IO Controller (IOC). If the IOC is already disabled, the command is ignored.

port_id

Specifies the ID of the port you want to disable.

--query

Queries the attributes of the Storage IOC with the IOC ID.

ioc_id

Specifies the port of the IO Controller (IOC) you want to enable.

--intr

Sets the interrupt attributes for the port.

port_id

Specifies the ID of the port on which you want to set interrupt attributes.

coalesce | c

Sets the coalesce flag.

on|off

Sets the interrupt attributes for the port to on or off.

-Latency

Sets the latency monitor timeout value. Latency can be between 0 to 225
microseconds. A latency value of 0 disables latency monitor timeout
interrupt. The default latency value is 5 for an HBA.

Advertising
This manual is related to the following products:

815, 425, 804, 825