2-way-distribution

valve N2W

841489903

2,1

Distribution valve to divide

one oil flow into two flows.

By closing or opening the

valve screw, the partial

flows could be regulated

and harmonized.

(Base plate is a basic

requirement)

Oil distributor with

pressure gauge

connection N4M

841489905

1,4

By use of the oil distributor

one oil flow can be divided

into 5 flows. The distributor

has 4 pressure ports

(G1/4”) and one pressure

gauge port (G1/4”).

(Base plate is a basic

requirement)

Mounting of base plates and valve blocks

6.

ATTENTION!

When mounting base plates and valve blocks, hydraulic fluid can leak from

the pump. To make sure that the quantity of the leaking fluid is as small as

possible, the hand pump should be in a vertical position with the hydraulic

ports facing upwards, while mounting base plates and valve blocks

Make sure to store all plugs, screw plugs and/or dust caps in a way that

prevents them from getting dirty or lost.

Especially you will have to take care that the eventually leaking hydraulic fluid

is being collected completely and being disposed professionally!