Lukas LH2 User Manual

Page 32

Advertising
background image

32

Hand pumps with a 1,8 l reservoir has to be disassembled like shown below:

nut (Pos. 16.1), sealing ring (Pos. 15.2), base plate, flat seal (Pos. 17.1), reservoir,

connecting plate and sealing (Pos. 15.1).

16.1 15.2

base plate

17.1

reservoir

17.1

connecting plate

15.1

Hand pumps with a 3,8 l reservoir has to be disassembled like shown below:

nut (Pos. 16.1), sealing ring (Pos. 15.2), base plate, flat seal (Pos. 18.1), reservoir,

connecting plate and sealing (Pos. 15.1).

5. The assembly is done in reverse order. Replace all damaged parts with new ones.

The tightening torque of the nut is 40 Nm.

base plate

reservoir

connecting plate

16.1 15.2

18.1

18.1

15.1

Advertising
This manual is related to the following products: