1. Put the base plate onto the pump head, so

that the boreholes “T” and “P” of the base

plates matches with the ports of the pump

head

Take care, that the surfaces are clean and

dust-free.

2. Put the 4 screws into the designated

boreholes and tighten them with a torque

of 20 Nm.

3. When you are connecting the hose assemblies directly to the hand pump, you will have

to mount appropriate designated couplings, fittings or closing screws to the ports “P” and

“T”. (tightening torque M

A

= 40 Nm)

6.2 Base plates

ATTENTION!

After the end of the assembly close all hydraulic lines by using closing screws

and/or dust protection caps, to prevent the hand pump from impurities.