11.5.5 Replacing pressure limiting valves and filter

The pressure limiting valves have to be replaced, when they are damaged. The filter has

to be replaced, when the flow of the hydraulic fluid is not possible or it is only possible with

difficulties.

ATTENTION!

Pressure limiting valves must not be disassembled or readjusted; they have to

be replaced by new ones with appropriate settings!

Procedure:

1. Disassemble reservoir, like described in chapter “Removing tank for cleaning, replacing

the tank or the seals”.

2. Demount the pressure limiting valve HP (Pos. 11.1/12.1), the pressure limiting valve LP

(Pos. 13.1) and the sealing rings (Pos. 11.2) below. When replacing the filter, demount

filter (Pos. 14).

13.1

11.1/12.1

11.2

11.2

14

high pressure port

low pressure port

3. The assembly is done in reverse order. Replace all damaged parts with new ones. The

tightening torque of the pressure limiting valves are 50 Nm.