Troubleshooting 12 – Lukas LH2 User Manual

Page 37

Advertising
background image

37

Troubleshooting

12.

Problem

Cause

Remedy

Connected device

does not move, moves

only slowly or moves

intermittently.

Fluid level in the hydraulic

tank too low

Add hydraulic fluid up to

max. fill level.

Hand relief valve open

Close hand relief valve.

Hose line not properly

connected or damaged

Check connection of the

hose line and reconnect it

if necessary.

Load on the device

too high

Use a different device.

Air in the hydraulic system Bleed system as described

in the chapter “Bleeding

the pump”.

Valve block defective

Replace valve block
Repair by an authorised

dealer or by LUKAS itself

Defect on the device

Heed the specifications

of the separate operating

instructions of the

device.

Connected device moves,

but does not hold pressure

or does not render the

specified performance.

Hose line not properly

connected or damaged

Check connection of the

hose line and reconnect it

if necessary.

Leaking seal

Locate the leak and have

the hand pump serviced by

an authorised dealer, by

personnel specially trained

by LUKAS or by LUKAS

directly.

Valve block defective

Replace valve block
Repair by an authorised

dealer or by LUKAS itself

Internal leakage of the

pump

Have the hand pump

serviced by an authorised

dealer, by personnel

specially trained by LUKAS

or by LUKAS directly.