39

In the case of a quick-

disconnect coupling

system: Leakage on the

male coupling

Safety valve has

responded (in the

decoupled state)

After depressurization, no

further leakage occurs.

Male coupling defective

Male coupling should be

replaced immediately.

In the case of a quick-

disconnect coupling

system: Leakage at the

female coupling

Female coupling defective Female coupling should be

replaced immediately.

Hydraulic fluid escaping

from the hoses or at the

joints

Leakage, possible damage Replace hoses.

Damage on the surface of

the hydraulic hoses

Mechanical damage or

contact with aggressive

media

Replace hoses.

Problem

Cause

Remedy

If the defects cannot be remedied, notify an authorised LUKAS dealer or contact LUKAS

Customer Service directly!

The address of LUKAS customer service is: