4 hand pump with 4/3-way valve, 5 hand pump with 2-way distribution valve – Lukas LH2 User Manual

Page 23

Advertising
background image

23

5. To reduce the pressure of the device, slowly open the discharge valve of the hand pump

(turn counter-clockwise). In this way, you can meter the pressure reduction precisely.

Make sure, that the discharge valve is opened completely and the tool is in basic position

before you disconnect the tool.

9.4 Hand pump with 4/3-way valve

1. Close discharge valve on the hand pump completely (rotate clockwise).

2. Connect the lines of the tool or the tools to the ports “A” and ”B”.

3. Move the locking pin into the operating position.

4. Choose with the lever, which line you will pressurize.

“A” means line “A”.

The middle position is the neutral position, this means none of the connected lines will be

pressurized when you are pumping.

“B” means line “B”.

5. Supply the device with hydraulic fluid or pressurise by operating the pump lever (up and

down movements).

6. To reduce the pressure of the device, slowly open the discharge valve of the hand pump

(turn counter-clockwise). In this way, you can meter the pressure reduction precisely.

Make sure, that the discharge valve is opened completely and the tool is in basic position

before you disconnect the tool.

9.5 Hand pump with 2-way distribution valve

1. Close discharge valve on the hand pump completely (rotate clockwise).

2. Connect the lines of the tool or the tools to the ports “A” and ”B”.

3. Move the locking pin into the operating position.

4. Open the hand wheel for the line(s) which you would like to pressurize.

“A” means line “A”.

“B” means line “B”.

According to the position of the valve hand wheels, the supply with hydraulic fluid could

be dosed.

5. Supply the device with hydraulic fluid or pressurise by operating the pump lever (up and

down movements).

6. To reduce the pressure of the device, slowly open the discharge valve of the hand pump

(turn counter-clockwise). In this way, you can meter the pressure reduction precisely.

Make sure, that the discharge valve is opened completely and the tool is in basic position

before you disconnect the tool.

NOTE:

A pressure decrease is also possible by switching the lever into the opposite

moving direction. In this case the pressure decrease could not be dosed, it will

carried out very abrupt.

Advertising
This manual is related to the following products:

LH1