11.6.2 4/3-way valve (locating disk and needle bearing replacement)

The lever parts must be replaced, when you see external damages or they do not work

correct.

Procedure (Demount of lever, locating disk and needle bearing):

1. Untighten the screws (Pos. 4) at

the cover plate and remove the

coverplate.

2. Remove the needle bearing (Pos. 3.2)

and the lever. After that disassemble

infolowing parts:

lever knob (Pos. 2), lever rod (Pos.

1), locating disk (Pos. 3.1) and needle

bearing (Pos. 3.2).

3. The assembly is done in reverse order. Replace all damaged parts with new ones.

1

2

3.2

3.1

4

cover plate

ATTENTION!

Below of the locating knob

are balls inserted in the

valve body.

This balls could fall out while

demounting.

Therefore it is important to

pay attention to these balls,

because otherwise the

functionality could not be

guaranteed.

balls