6 repair (accessories) – Lukas LH2 User Manual

Page 34

Advertising
background image

34

11.6 Repair (accessories)

11.6.1 4/3-way valve (lever replacement)

The lever parts must be replaced, when you see external damages or they do not work

correct.

Procedure (Demount only the lever rod and the lever knob):

1. Dismantle the lever knob (Pos. 2).

2. Dismantle the lever rod (Pos. 1).

(If needed, use tongs)

3. The assembly is done in reverse order. Replace all damaged parts with new ones.

1

2

ATTENTION!

Because LUKAS devices are designed for the highest performance, only

components may be replaced that are listed in the spare parts lists of the

corresponding device and whose replacement is described here.

Additional components of the equipment may only be replaced if:

- You have participated in a corresponding LUKAS service training course.

- You have the express permission of LUKAS customer service (by request,

check on the grant of permission. A check is necessary in each

individual case).

Advertising
This manual is related to the following products:

LH1