Lukas LH2 User Manual

Page 31

Advertising
background image

31

ATTENTION!

Properly dispose of the removed

hydraulic fluid and all damaged com-

ponents!

9.1

9.2

11.5.4 Removing tank for cleaning, replacing the tank or the seals

The tank should be cleaned at least once per year in order to remove the accumulated dirt.

The tank must be replaced if there is any external damage that impairs the safety of

the device.

The tank seals must be replaced if there are any leaks at the junction points of the tank.

Procedure:

1. Emptying the reservoir by demounting the

plug screw (Pos. 9.1) and the sealing ring

(Pos. 9.2) below and after that emptying

the reservoir.

2. Demount nut (Pos. 16.1) and sealing ring (Pos. 15.2) below.

3. Remove base plate and sealing (Pos. 15.1).

4. Remove reservoir and sealing (Pos. 15.1).

16.1

15.2

base plate

15.1

reservoir

15.1

Advertising
This manual is related to the following products:

LH1