Machine controls with option “auto-level” at ground

level

Emergency stop button. To stop operation in emergency the button should be
pushed in. For operation this button must be pulled out. (The platform controls
also has an emergency stop button, which must be out for the controls to work.)

Selector switch. This keyed switch is a three position switch. If the switch is in
the middle position the power to the controls are shut off. If the switch is in
the right or clock-wise position the controls are active at ground level. If the
switch is in the left position or the counter-clock-wise position, the controls are
active on the platform.

The raise-lower selector switch. This switch is only active when the enable
button is pushed. These two controls must be operated together. When the
enable button is pushed, the up-down selector controls the platform raise and
lower function.

The „level machine‟ button. This button is for auto-level. All the preconditions
and set up are pre-conditions for this button to work. The outriggers, however,
must be positioned and the legs locked. The machine will „auto-level‟. That is if
the legs are positioned and pinned properly, the operator must push this green
button marked “Level Machine” and the legs will extend and the machine will
level automatically. If the machine does not level, several things could cause
the problem. (See the section “If machine will not level.” Page 23)