Setting Up a Wiegand System

Responding to Activator IDs
By default, the Receiver will only output Wiegand data from

Tags activated by Activator ID

127

. Use the following

commands to modify the way the Receiver responds to

Activator IDs.

Command

Action

<number>W Change Activator ID

(This is known as the Wiegand ID. The default is to

only output reads corresponding with this Activator)

33c

Respond to multiple Activator IDs

(Wiegand output of the Receiver will now include all

tag reads from Activators listed as valid Activator IDs

for serial output in addition to the Wiegand ID)

19c

Disable multiple Activator IDs

(Returns the Wiegand output to the single Wiegand

Activator ID)

Alarm Output
By default, the Network Receiver does not output Tag data

containing alarm codes from Panic and Tamper Tags via the

Wiegand port. Use the following commands to enable or

disable alarm data output.

Command

Alarm

26c

Enable output Tag data containing alarm codes

from Panic or Tamper Tags

(By default, the Receiver does not output alarm data)

12c

Disable alarm data output

(Default)

Setting Up a Serial or LAN System

Setting the Baud Rate
The following commands are available for configuring the

Network Receiver’s serial port:

Command

Action

23c

Set baud rate to 4800

24c

Set baud rate to 9600

25c

Set baud rate to 19,200 (default)