Responding to Activator IDs
The Receiver will

only output Tag data via the serial port if it

contains a valid Activator ID.

By default, The Network Receiver accepts Tag data from

Activators with the following IDs:

0

3

13

14

21

22

24

27

33

34

44

47

52

55

57

58

69

70

72

75

80

83

93

94

100

103

105

106

113

114

124

127

254

255

Figure 5 Default Activator IDs

Editing Activator IDs within the Receiver
Use the following commands to add, delete and reset the

Activator ID numbers within the Receiver:

Command Action

<number>- Delete unwanted ID(s) from the Receiver’s list

37c

Remove all accepted Activator IDs

(Receiver will still pass default ID 127)

<number>+ Add an Activator ID

34c

Reset the list to the valid Activator ID numbers

When editing the Activator IDs within the Receiver, you may

observe the following error codes.

Code

Reason

04

Trying to delete an ID that has not been

programmed

03

Trying to delete all IDs. Must be at least one ID.

02

Trying to enter more than 34 IDs – the max.

(Delete some Activator IDs on the list to make room)

01

Duplicate entry