Appendix C: Network Receiver Commands

NOTE

All bolded commands are default settings

<number>D

set control TTL output 1 signal duration time in seconds (0-255,5)

<number>E

set control TTL output 2 signal duration time in seconds (0-255,5)

<number>

I

set Device ID for Network Receiver (0-999)

<number>L

set tag redundancy buffer time in tenths of seconds (0-255, 125)

<number>T

set time between tag read outputs in tenths of seconds (0-255, 13)

<number>W set single valid Wiegand Activator ID (1-250, 127)

<number>+

add new Device ID or Status Code to Valid ID list (0-255, max 34)

<number>-

delete a Device ID or Status Code to Valid ID list (0-255, min. 1 entry)

<number> >

add new Device ID or Status Code to Valid Wiegand ID list (0-255, max. 34)

<number> <

delete a Device ID or Status Code to Valid Wiegand ID list (0-255, min. 1 entry)

10c

turn on TTL output 1 now

11c

turn on TTL output 2 now

12c

set Wiegand alarm output to OFF

13c

set TTL output 1 alarm flag to OFF

14c

set TTL output 2 alarm flag to OFF

15c

set Wiegand output to ON

16c

set TTL output 1 valid read flag to OFF

17c

set TTL output 2 valid read flag to OFF

18c

set tag read serial output to ON

19c

set Wiegand Activator ID filter to ON

20c

set Wiegand/TTL output interrupts to ON

21c

set serial output to the long format (RRRAAAFFFTTTTT)

22c

set serial diagnostics output to OFF

23c

set serial data rate to 4800 baud

24c

set serial data rate to 9600 baud

25c

set serial data rate to 19200 baud

26c

set Wiegand alarm output to ON

27c

set TTL output 1 alarm flag to ON

28c

set TTL output 2 alarm flag to ON

29c

set Wiegand output to OFF

30c

set TTL output 1 valid read flag to ON

31c

set TTL output 2 valid read flag to ON

32c

set tag read output to OFF

33c

set Wiegand Activator ID filter to OFF

34c

set Valid ID list to default values (per V5 list)

35c

set Wiegand/TTL output interrupts to OFF

36c

set serial output to short format (AAAFFFTTTTT)

37c

clear Valid ID list (except 127)

38c

return and display current configuration data

39c

set serial diagnostics output to ON

40c

return and display Supervisory data

41c

enable the Wiegand ID list

42c

disable the Wiegand ID list

43c

clear Valid Wiegand ID list (except 127)

44c

set Valid Wiegand ID list to default values (per V5 list)