Axcess Network Receiver Installation Guide User Manual

Page 20

Advertising
background image

Network Receiver

20

750.001.005 R04

© 2005 AXCESS Inc.

5.

TTL output 1 on valid read, when enabled any read from a tag

will cause TTL 1 to be triggered. Default OFF “16c”

6.

TTL output 2 on valid read, when enabled any read from a tag

will cause TTL 2 to be triggered. Default OFF “17c”

7.

Serial data output, allows the user to disable or enable the RS-

232 or TCP/IP output. Default ON “18c”

8.

Wiegand Activator ID filter, enables or disables the single

Activator ID in the config line (i.e. W = 127). Default ON “19c”

9.

Serial Data format, Sets the serial data format to long or short to

support older versions of the Axcess RFID products. Default

Long “21c”

10.

Diagnostic mode, enables or disables diagnostic mode. If in

diagnostic mode the receiver will output data the Wiegand, Serial

and TCP/IP without checking the Activator ID filter. Default OFF

“22c”

11.

TTL and Wiegand Timers, enables or disables the timers for the

TTL and Wiegand outputs. Default ON “20c”

12.

Wiegand Activator, enables or disables the Wiegand Activator list

.

Default OFF “42c”

D=005 E=005

Time in seconds that the TTL Outputs will go from LOW to High (from

0 V DC to 5 DC). This value can range from 1 to 255 seconds. D is

TTL Output One and E is TTL Output Two. Default 005

I=001

This Receiver ID, this value can range from 001 to 255. Default 001

L=125

The period of time the receiver will not output any additional tag

reads of duplicate tag ID’s, new tag ID’s will still be output, out the

Wiegand port. The above value is 12.5 seconds. Default 125

T=013

The period of time between tag ID’s being output the Wiegand port.

This is buffer is used to prevent the tag ID’s from being sent to fast to

the Wiegand panel. The above value is 01.3 seconds. Default 013

W=127

The Activator ID which data will be output on to the Wiegand port, if

enabled. (by default this list is enabled).