Setting the Receiver ID

Receiver IDs are used by ActiveTrac software to determine from

which zone a Tag reported. By default, the Receiver ID is 001. To give

the Receiver a new ID, type:

<number>I (<

number

> = a number between 000 and 999.)

Enabling TTL Outputs (Logic Control)

The Network Receiver has two TTL outputs (Transistor-Transistor-

Logic). Each can be set to go from Low (inactive) to High (active) upon

a Tag read. The output level is 3.3 V DC. The following table provides

a list of configuration commands:

TTL Output 1 TTL Output 2 Action

<number>D

<number>E

Set length of action signal in seconds.

Valid numbers are 000 – 255. Default:

005 seconds

10c

11c

Pulse the output to go from Low to

High

16c

17c

Deactivates TTL output for a valid Tag

read. Default.

30c

31c

Activate TTL output for a valid Tag read.

13c

14c

Do not activate TTL output when the

alarm code is received from a Panic or

Tamper Tag. Default.

27c

28c

Activate TTL output when an alarm

code received is from Panic or Tamper

Tag