Axcess Network Receiver Installation Guide User Manual

Page 16

Advertising
background image

Network Receiver

16

750.001.005 R04

© 2005 AXCESS Inc.

Serial Output Format
The default format for Tag data sent out the serial port of the

Receiver is:

R R R A A A F F F T T T T T LF CR

R

= Receiver ID

A

= Activator ID

F

= facility code

T

= Tag ID number

LF

= Line Feed

CR

= Carriage Return

To make the Receiver backwards compatible with AXCESS NT

132 systems, type:

36c

. The serial output will now have the

short format. To return to the long format (default), type:

21c

Optimizing Serial Output
The speed at which the Network Receiver processes data can

be maximized by eliminating extra steps required to output

Wiegand data and check TTL output control settings. Use the

following commands to optimize the serial output:

Command

Action

29c

Turn off Receiver’s Wiegand output

15c

Restore Wiegand output

(Default)

35c

Disable TTL outputs

(If your installation does not require TTL outputs,

the serial output can be optimized by disabling

them. This will also disable Wiegand outputs)

20c

Restore TTL output operations

TIP

When the Network Receiver is sending data via the serial port,

the LED labeled DATA TX will alternately flash from red to green.

Observing this LED on the front of the unit will help in verifying

proper operation of the Receiver

.