13. Lower the

Tractor Drive Cover, and tighten until the tracks make contact

with the cable. Give one additional turn to the clamp screw.

14. Turn on Hydraulic Power, and press the ECB DRIVE button ON.

15. Increase speed as quickly as possible by turning the

hydraulic Flow Control

counter-clockwise. The Cable should be pushed into the duct. Continue to
speed up the tracks until the cable stops and the ECB gives a
hI-PRESSuRE ERROR screen.

16. If a

hI-PRESSuRE ERROR appears, follow the on-screen instructions to

reset the electronics and return to the Operations screen.

17. Raise

Tractor Drive Cover. Pull out 8' (2.4m) of cable from the blower.

18. Lower and tighten

Tractor Drive Cover. Repeat steps 6-7 to increase the

pressure by 50 PSI.

19. Repeat steps 12-16 until cable damage

is seen – either in the form of jacket
damage or bends in the cable, the
cable folds over, or you reach 1500 psi.
You will notice cable fold-over because
the line drawn on the cable will
disappear inside the machine or duct.
(Figure 17).

20. Repeat steps 6 and 7 to reduce the

PRESSuRE LImIT by 50 PSI.

21. Remove folded fiber and test again at

current

PRESSuRE LImIT settings to

ensure no fiber fold over or
damage occurs.

22. Remove test piece of fiber optic cable.

23. If the re-test is confirms no cable damage, Re-adjust

Flow Control setting to

the slowest speed.

24. Remove test duct piece from the Deluxe Blower.

25. Crash test is complete.

15

Figure 17. Cable folds over