Condux Deluxe Blower User Manual

Page 31

Advertising
background image

31

SCALE: Touching the touch screen on any of the Units (FPM/MPM, FT/M,

PSI/BAR) will open a UNITS screen. Select from Metric or Imperial units, and
press

ENTER.

SPEED: Displays cable speed in Feet/Min or Meters/Min

DIST: Displays distance of current installation in Feet or Meters – Resettable

RESET: Touch Screen button that will reset DIST to 0

TOTAL: Displays lifetime distance on the machine in Feet or Meters –

Non Resettable.

PRSSR: Displays hydraulic working pressure in PSI or BAR. This pressure should

match the pressure shown on the analog pressure gauge.

LImIT: Displays the pressure limit set point in PSI or BAR. When the PRSSR value

exceeds this set limit, the tractor drive will be stopped. This feature is NOT
dependent on having the

TRACTION CONTROL system turned ON. To change

the

LImIT value, touch the screen in the LImIT: xxxx area, and a keypad will

appear. Enter the desired limit value and press ENTER to save the new value.
Press

ESC to exit screen without saving the new value.

When the pressure

LImIT is exceeded, the display will show:

HI-PRESSURE ERROR – follow on-screen instructions and press

RESET at

bottom of screen to return to operation (Figure 66).

EmERGENCY STOP BuTTON: Press the Emergency Stop button at any time to

immediately stop the tractor drive. When the Emergency Stop button is pressed,
the display will show:

!!EMERGENCY STOP!! – follow on-screen instructions and press

RESET at

bottom of screen to return to operation. The EMERGENCY STOP screen will not
clear until the Emergency Stop button is pulled up (Figure 66A).

Figure 66A. Emergency Stop

Figure 66. hi-Pressure Error