D. OPERATIONAL CAPACITIES

• Pushing Force: 175 lbs (778 N) maximum

• Pushing Speed: 300 ft/min (91 m/min) maximum

• Cable Sizes: .25" to 1.13" (6 mm to 28.7 mm)

• Conduit Sizes: 1/2", 3/4", 1", 1-1/4" TRUE, 1-1/4", 1-1/2" SDR 11 & 13.5,

2" and metric O.D. conduit; 10 & 12 mm, 12.7 mm, 14 mm, 16 mm,

18 mm, 25 mm, 32 mm, 36 mm, 37 mm, 40 mm, 42 mm, 44 mm, 46 mm

and 50 mm

E. ELECTRONIC CONTROL BOx

• Power Requirements: 12 volts DC

• Power consumption is 24 Watts

• Power connection must be to automotive power point or power point

connection on Condux hydraulic power unit

• Fused with a 2.5 amp fuse, 250 volt-5x20mm-GMA type

• Displays: Total Machine Distance, Distance of Run, Operational Speed,

Errors Descriptions

• Automatic Shutdown Speeds: 300 ft/min (91 m/min) maximum

F. PhYSICAL SPECIFICATIONS (DOES NOT INCLuDE LEGS OR jOB BOx)

• Height

16.5" (419 mm)

• Length

30" (761 mm)

• Width

14.8" (375 mm)

• Weight

82 lbs (37 kg)

G. ACOuSTIC EmISSION

• Level of max. sound pressure to the operator seat (ISO 11202) Lep=85 dB(A)

h. CATERPILLAR DRIVE SPECIFICATIONS

• Maximum pushing force: 175 lbs (778 N), depending on cable diameter

• Maximum pushing speed: 300 ft/min (91.5 m/min)

• Maximum clamping force: <114 lbf/in (20 N/mm)

• Independent pushing drive belts with polyurethane pads profiled for cable

0.23" (5.8 mm) to 1.13" (28.7 mm)

• Mechanical gas charged shock absorber clamp to prevent cable crush.

• Side guards.

I. CONDuIT COuPLING REQuIREmENTS

• Must withstand maximum air pressure of 175 psi (12 bar).

• Must withstand axial loading and vibration.

• Must be screw type, compression type, or fusion type.

• Sight Holes must be sealed.

• Must fit snugly.

• Conduit ends must be cut off squarely and deburred.

• Conduit must be fully seated into the coupler.

• Couplers should be installed in a straight section of conduit.

• Must be same size conduit.