Tear down procedures – Condux Deluxe Blower User Manual

Page 34

Advertising
background image

34

!wARNING: Air Block Assembly contains compressed air when blower
is operated. Opening Air Block while under pressure may cause serious

personal injury. Ensure blower is depressurized before removing Air

Block cover.

7. Remove

Cable Grip from receiving end of Conduit.

8. If electronics stop blower before

Cable Carrier exits, restart blower, making sure

speed is within minimum and maximum allowance. Also see Troubleshooting
Guide.

Tear Down Procedures

!wARNING: Air Block Assembly contains compressed air when blower is
operated. Opening Air Block while under pressure may cause serious personal
injury. Ensure blower is depressurized before removing Air Block cover.

A. REmOVE POwER FROm uNIT.

1. Turn off compressed air by closing the

Air Control Valve at the blower

(Figure 71). Shut off air at the compressor and decompress air hose.
Depressurize the air block by turning the air control valve to the 9 o’clock
position (Figure 72). Remove air hose when system is relieved of pressure.

2. Raise

Tractor Drive Cover with turn crank (Figure 73).

3. Turn off

hydraulic Power Supply and disconnect hydraulic hoses (Figure 74).

Keep all connections free of dirt and particles. Use hose end caps (supplied).

4. Disconnect electronic cords.

!wARNING: Escaping fluids under pressure can penetrate the skin and

cause serious personal injury. Release pressure before disconnecting

hoses.

12.

Figure 71. Turn Off Air at the

Air Block

Figure 72. Decompress Air Block

Advertising