7. Close the

Air Block Cover. Tighten spanner nuts securely, but do not over

tighten (Figure 41). Use cross tightening procedure with the spanner wrench to
secure completely.

8. Prove conduit integrity and spread lubricant through Conduit.

a. Re-connect the air hose to the fiber blower and attach all safety clips.

b. Turn the

Air Control Valve handle to the 12 o’clock position and turn on the

air from the compressor (Figure 42).

c. Slowly open

Air Control Valve by turning to the 3 o’clock position.

d. Blow

Foam Carrier through conduit to spread lubricant and check for

blockage. Follow all safety precautions.

e. After the

Foam Carrier exits, close Air Control Valve.

NOTE: Foam Carrier must exit in a reasonable time, allow for approximately
10 seconds per 1,000 feet (300 m) or conduit may be contaminated or blocked.

23

Figure 39. Insert Foam Carrier

Figure 40. Insert Seal Disk