2. Remove the pivot shaft with an 8 mm allen wrench.

3. On the bottom drive, remove the 3 capscrews from the prox cover with a 2 mm

allen wrench.

4. The bearing cap can be removed from both the top and bottom assembly using

a 5 mm allen wrench.

5. At this point, the drive pulley can be removed straight out the same hole as the

bearing cap and the belt can be removed. This sequence is reversed for the
reassembly of the new belt with a key note,

the dampening bushing must be

rotated back to the smaller lobe position on the pivot shaft.

NOTE: Become familiar with the Replacement and Wear Parts associated with
the LW Blower, they are listed in Appendix T pg. 59.

Figure 78. Torque Specifications for Steel into Steel

Figure 79. Torque Specifications for Steel Capscrew into Aluminum