10. Plug receiving end of

Conduit with a properly sized Conduit Pulling Eye

(Figure 28) (Appendix R pg. 62).


11. Choose the correct

Pulling Grip & install on receiving end of Conduit

(Figure 29).

12. Connect the

Air Compressor (Figure 30).

a. Ensure

Air Valve is off before connecting air hose.

b. Attach the hose supplied with the air compressor to the air compressor
coupling. The blower air valve assembly is equipped with a claw type
connector. Use safety clips on all pneumatic hose connections (Figure 31).

c. Observe all safety procedures.

d. Route all hoses properly to prevent tripping over them.

!wARNING: Forced air creates flying debris. Always wear personal

protective equipment. Severe personal injury could result.

!wARNING: Ensure no personnel are in the destination access vault

during the blowing operation. Severe personal injury could result.

Figure 28. Installing Conduit

Pulling Eye

Figure 29. Installing Pulling Grip

OPERATOR

HYDRAULIC

POWER

SOURCE

INNERDUCT

AIR HOSE

FIBER

OPTIC CABLE

ELECTRICAL HOOK UP

TO POWER SOURCE

CABLE

REEL

HYDRAULIC

HOSES

DELUXE LW

BLOWER

AIR

COMPRESSOR

Figure 30. Typical Connections

Figure 31. Installing Air hose with

Safety Clips