Blower operating instructions – Condux Deluxe Blower User Manual

Page 28

Advertising
background image

28

ImPORTANT: It is recommended that if a reel-tensioning unit is not being used,
the cable reel should then be kept under control by a second operator who is
required to wear proper safety equipment and maintain a proper distance from
the cable.

A. FINAL INSPECTION

!CAuTION: Before placing the blower into operation, always perform a

final inspection of all components used.

1. Check that the

Cable Grip is attached to conduit on receiving end.


2. Notify crew that preparations are complete and cable blowing is to begin.

Blower Operating Instructions

A. OBSERVER AT ExIT PIT
Station an observer with a 2-way communication device, at the far end of the Conduit,
where the Cable carrier will exit.

B. CONNECT ThE hYDRAuLIC SYSTEmS (Figure 59)
The Deluxe Blower’s hydraulic system uses quick-disconnect couplings. Keep all
connections clean to avoid contamination and possible system failure. Use hose end
caps (supplied). A contaminated hydraulic system will effect the operation of the
cable blower and may invalidate your product warranty. Take caution in routing the
hoses to prevent a tripping hazard. Follow these steps to connect the hydraulic
components:

1. Attach the quick-disconnect couplings to the hydraulic power supply (Figure 60).

2. Start the hydraulic power unit and check all connections for leaks with a piece

of cardboard. In cold weather, run hydraulic power supply until hydraulic oil
warms up.

OPERATOR

HYDRAULIC

POWER

SOURCE

INNERDUCT

AIR HOSE

FIBER

OPTIC CABLE

ELECTRICAL HOOK UP

TO POWER SOURCE

CABLE

REEL

HYDRAULIC

HOSES

DELUXE LW

BLOWER

AIR

COMPRESSOR

Figure 59. Typical Set-up

Figure 60. Attach hydraulic

hoses

11.