3.4. Motor Power – J8

Pin (J8) Signal Function

1

PTC

Positive Temperature Coefficient

2

PTC

Positive Temperature Coefficient

3

N/C

Not Connected

4

N/C

Not Connected

AC Motor

DC Motor

5

PE

Protective earth

Motor

Motor

6

M1

Motor phase

Motor

N/C

7

M2

Motor phase

Motor

Motor

8

M3

Motor phase

Motor

Motor

Pin Positions

Note:

When connecting several drives to several motors, all should be wired in the same motor

phases and feedback sequences. This will enable the same SimplIQ program to run on all drives.