Motor power – j8 – ElmoMC SimplIQ Digital Servo Drives-Whi-Solo Installation Guide User Manual
Page 19
Advertising
Solo Whistle Installation Guide
Installation
MAN-SOLWHIIG (Ver. 1.503)
19
3.4. Motor Power – J8
Pin (J8) Signal Function
1
PTC
Positive Temperature Coefficient
2
PTC
Positive Temperature Coefficient
3
N/C
Not Connected
4
N/C
Not Connected
AC Motor
DC Motor
5
PE
Protective earth
Motor
Motor
6
M1
Motor phase
Motor
N/C
7
M2
Motor phase
Motor
Motor
8
M3
Motor phase
Motor
Motor
Pin Positions
Note:
When connecting several drives to several motors, all should be wired in the same motor
phases and feedback sequences. This will enable the same SimplIQ program to run on all drives.
Advertising