Solo Whistle Installation Guide

Installation

MAN-SOLWHIIG (Ver. 1.503)

www.elmomc.com

22

3.5.1.

Connecting Main Power

Power to the Solo Whistle is provided by a 12 to 195 VDC source. A smart control-supply
algorithm enables the Solo Whistle to operate with the power supply only in up to 100 V
models, with no need for an auxiliary 24 volt supply.

200 V models always require two separate power supplies.

If backup functionality is required (for storing control parameters in case of power-outs) an
additional backup supply can be connected by implementing "diode coupling" to the VL+.

Note:

The source of the 12 to 195 VDC Main Power Supply must be isolated.

Figure 4: Main Power Supply Connection Diagram