3 units of measurement, 1 position, Ole_link3 – ElmoMC SimplIQ Software Manual User Manual

Page 12: 3 units of measurement -3, Position -3

Advertising
background image

SimplIQ

Software Manual

Communication with the Host

MAN-SIMSW (Ver. 1.4)

2-3

ƒ

Tools for associating functions to I/O connector pins

ƒ

Automatic current controller tuning

ƒ

Automatic commutation tuning

ƒ

Manual, advanced manual and automatic speed controller tuning

ƒ

Manual, advanced manual and automatic position controller tuning

ƒ

Smart Terminal, for direct user interface using RS-232 or CAN

ƒ

A recorder with advanced scope controls, for observing up to eight signals
simultaneously, triggered by a selection of events

ƒ

Application database maintenance: save and load application database, and edit
application parameters, with help

ƒ

Advanced IDE for user program development:

ƒ

Editor

ƒ

Compiler

ƒ

User program upload and download

ƒ

Debugger with: breakpoint and stepping options, watches for local and global
variables, call stack watch

The Composer software reads the personality data from the

SimplIQ

drive and can

thereby adapt to the specific drive model.

2.3

Units of Measurement

This section describes the units of measurements used by the

SimplIQ

drive for time,

position, speed, voltage and current.

2.3.1

Position

The

SimplIQ

drive refers to position using sensor counts, which may be related to

physical units using the following commands:

Command Description
CA[18]

For rotary motors, CA[18] is the number of sensor counts per one full
mechanical revolution.

CA[23]

For linear motors, CA[23] stores the number of counts per user unit
(meter or any other unit selected by the user). This value is stored for
convenience only; the

SimplIQ

software does not use this number for any

internal calculation. For rotary motors, set CA[23]=0.

YA[1], YA[3]

YA[1] is the auxiliary feedback resolution, in counts/physical unit. YA[3]
indicates what that physical unit is: revolution, meter or other. YA[1] and
YA[3] are stored for convenience only; the

SimplIQ

software does not use

these numbers for any internal calculation.

Advertising