The following user program performs the algorithm:
function [int status] = homing1(int TimeOut)

/*

Homing routine.

Input:

TimeOut: Timeout for failure

Output:

status=1 if o.k., otherwise a negative error code

Assumptions:

RLS,FLS,HOME already programmed by IL[1],IL[2],IL[3] commands

*/

int OldMi;

/* Go reverse until limit switch */

OldMi=MI;MI=MI|0x16; /* Prevent operational AUTO_RLS routine while in

homing process*/

/* Arm homing for

↑RLS, stop after homing, don't initialize counter*/

HM[3]=7;HM[4]=0;HM[5]=2;HM[1]=1;

/* Go to the reverse */

JV=-10000;BG;WaitArrive(2000);if(status<=0)goto LastLine; end

/* Go until home switch*/

HM[3]=1;HM[4]=2;HM[5]=2;HM[1]=1;

JV=-JV;BG;WaitHome(2000);if(status<=0)goto LastLine; end

/* Finallyset position by index */

HM[3]=3;HM[4]=0;HM[5]=0;HM[1]=1;

WaitHome(2000);if(status<=0)goto LastLine; end

status=1;/*Success return */

##LastLine

MI=OldMI; ** Restore AUTO_RLS routine status

return

Note that this function uses MI to prevent RLS and Home from activating the AUTO_RLS
and AUTO_HM routines, respectively. Another possible approach would be to use IL[N]
to change the functionality of the switch to GPI (general-purpose input) and then home
on the GPI. However, with the latter approach, the programmer must know which
connector pin is programmed as RLS.

The following auxiliary functions were used with the algorithm:
function [int status]=WaitArrive(int TimeOut)

/*

Wait until MS=0, or until too much time elapses

*/

int StartTime ;

status = -1;

StartTime = TM;

while (MS)

if ( tdif(handle) >= TimeOut) return ; end

end

status = 1 ;

Advertising