4 unit mode 4: dual feedback mode, 4 unit mode 4: dual feedback mode -9, Simpliq – ElmoMC SimplIQ Software Manual User Manual

Page 139

Advertising
background image

SimplIQ

Software Manual

Unit Modes

MAN-SIMSW (Ver. 1.4)

10-9

Software

position

com m and

Σ

Enable if

RM==1

Stepper angle

com m and

W S[20]

Torquecom m and

(DV[1], Am p)

Auxiliary position

com m and

Stop

m anager

Stop and lim it

switches

Sm oother

Torque

com m and

Current

controller

1024 count

per electrical rev.

Figure

10-8: Stepper Mode (UM=3)

The stepper angle command is generated by:
ƒ

The position software command generator

ƒ

The position auxiliary command generator

ƒ

The position stop manager

The generation of the stepper angle command is similar to position command generation
in UM=5. The torque command is simply given by the TC command.

10.4 Unit Mode 4: Dual Feedback Mode

Dual feedback mode is used when different sensors are used for speed/commutation and
for position. This is a mode commonly used when the motor drives the load through a
reduction gear. The controlled position is that of the load. However, the load position
may not be appropriate for commutation or speed feedback because:
ƒ

The commutation accuracy is limited by backlash and gear compliance.

ƒ

The motor speed can be measured with better resolution and less delay since the
motor rotates much faster than the load. In addition, the speed sensor is not subject to
dead zones caused by backlash.

Advertising