2 speed controller parameters, Speed controller parameters -3 – ElmoMC SimplIQ Software Manual User Manual

Page 221

Advertising
background image

SimplIQ

Software Manual

The Controller

MAN-SIMSW (Ver. 1.4)

15-3

DV[2]

Σ

Speed com m and

-

Torquecom m and

(DV[1], Am p)

Speed

controller:

KP,KI

High order

filter

Σ

FF[1]

d/dt

Autom atic

Controller

Selector

0

Fixed if

GS[2]=0

Position sensor

Speed

Estim ator

Encoder pulse

tim er

Speed feedback

Figure

15-1: Speed Controller Block Diagram

15.1.2 Speed Controller Parameters

The basic continuous-time PI controller is:

s

s

K

K

P

I

+

where:
K

I

is the integral parameter.

K

P

is the proportional parameter.

When using the scheduler, K

I

and K

P

are functions of time. When not using the gain

scheduler, they are fixed.

The input to the PI element is the speed error e

SPEED

(t) [Internal speed units]:

)

(

)

(

)

(

t

ack

SpeedFeedb

t

nd

SpeedComma

t

e

SPEED

=

The output to the current command I(t) in ampere units is:

⎟⎟

⎜⎜

+

=

)

(

)

(

)

(

)

(

0

t

p

t

e

K

d

e

K

K

t

I

SPEED

P

t

SPEED

I

Speed

τ

τ