13BFilters

MAN-SIMSW (Ver. 1.4)

14-3

Parameter Description

Value

Range

KV[65]…KV[69]

Parameters of fourth link

KV[70]…KV[74]

Parameters of fifth link

Table

14-3: Position Controller High-order Filter Parameters

The sensor filter parameters are:

Parameter Description

Value

Range

KV[75]

Is filter active?

0: Filter not active and bypassed. All
other filter parameters are ignored.
100: Filter is active.

KV[76]

Last index in KV[N] used
for this filter

76+5n, where 1 ≤ n ≤ 2 is the number
of used second-order links. The
maximum resulting filter order is 4.

KV[77]…KV[81]

Parameters of first link

KV[82]…KV[86]

Parameters of second link

Table

14-4: Sensor Filter Parameters

The parameters of the analog speed reference filter are:

Parameter Description

Value

Range

KV[87]

Is filter active?

0: Filter not active and bypassed. All
other filter parameters are ignored.
100: Filter is active.

KV[88]

Last index in KV[N] used
for this filter

88+5n, where 1 ≤ n ≤ 2 is the number
of used second-order links. The
maximum resulting filter order is 4.

KV[89]…KV[93]

Parameters of first link

KV[94]…KV[99]

Parameters of second link

Table

14-5: Analog Speed Reference Filter Parameters