Chapter 10: Unit Modes

The

SimplIQ

drive’s feedback can be structured in a number of different ways. These

options are called “unit modes” and are programmed by the UM parameter. The unit
mode can be switched only with the motor turned off, because the feedback structure
must be rearranged for each different mode. The following unit modes are available:

Value Description

(Related

Commands)

1 Torque

control

mode

2

Speed control mode

3 Micro-stepper

mode

4

Dual feedback position control mode

5

Single feedback position control mode

Table

10-1: Unit Modes

10.1 Unit Mode 1: Torque Control

In this mode, the drive controls the motor torque only. The drive may serve as a torque
driver, controlled by an external controller, with commutation performed to achieve the
maximum torque for the defined motor current.

If position sensors are connected, the position and speed are evaluated so that the drive
will abort upon over-speed, as specified by parameters LL[2] and HL[2].

The torque command may be set by a software command, an analog input or a
combination of the two, according to the following figure:

TC

Analog input 1

)

-

10 to 10 Volts(

AG ]

1

[

Amp/Volt

Σ

Enable if RM

==

1

Torque command

)DV

]

1

[

, Amp(

Σ

AS ]

1

[

-

Stop

Manager

Figure

10-1: Unit Mode 1 (Torque) Structure