SimplIQ

Software Manual

13BFilters

MAN-SIMSW (Ver. 1.4)

14-2

Filter Parameters

Maximum

Order

Speed controller high-order filter

KV[0]…KV[47]

Position controller high-order filter

KV[48]…KV[75]

Analog position sensor filter

KV[76]…KV[87]

Order 4 (2 blocks)

Analog reference to speed controller

KV[88]…KV[99]

Order 4 (2 blocks

Table

14-1: KV[N] Filter Parameters

The high-order filter parameters of the speed controller are as follows:

Parameter Description

Value

Range

KV[0]

Is filter active?

0: Filter not active and bypassed. All
other filter parameters ignored.
100: Filter is active.

KV[1]

Last index in KV[N] used
for this filter

1+5n, where 1 ≤ n ≤ 9 is the number
of used second-order links. The
maximum resulting filter order is 18.

KV[2]…KV[6]

Parameters of first link

KV[7]…KV[11]

Parameters of second link

KV[12]…KV[16]

Parameters of third link

KV[17]…KV[21]

Parameters of fourth link

KV[22]…KV[26]

Parameters of fifth link

KV[27]…KV[31]

Parameters of sixth link

KV[32]…KV[36]

Parameters of seventh link

KV[37]…KV[41] Parameters of eighth link

KV[42]…KV[47]

Parameters of ninth link

Table

14-2: Speed Controller High-order Filter Parameters

The high-order filter parameters of the position controller are as follows:

Parameter Description

Value

Range

KV[48]

Is filter active?

0: Filter not active and bypassed. All
other filter parameters ignored.
100: Filter is active.

KV[49]

Last index in KV[N] used
for this filter

49+5n, where 1 ≤ n ≤ 5 is the number
of used second-order links. The
maximum resulting filter order is 10.

KV[50]…KV[54]

Parameters of first link

KV[55]…KV[59]

Parameters of second link

KV[60]…KV[64]

Parameters of third link