5 viewing the resources – ElmoMC Multi-Axis Motion Controller-Maestro Installation Guide User Manual

Page 35

Advertising
background image

1. Select a CAN bus.
2. Click the right mouse button.
3. Select Insert.
4. Select IO.

5. Select Node ID.
6. Give the IO a name (such as IO)
7. Select a Type (DS401).
8. Select the I/O Sub Type (DIN for input and

DOUT for output devices).

9. Click OK.
10. Repeat for each of the other CAN input

devices.

Note: For devices having the input and output
functionality simultaneously, you need to provide
two different logical names for the input and
output partitions. For example: Device_IN and
Device_OUT respectively.
Note: To change I/O resource parameters, you
must remove old I/O logical object and replace it
with a new one which consisting of the desired
changes.

4.6.5

Viewing the Resources

Once the Axes and vectors have been set up, it is a good idea to check them. This is done
by expanding the CAN Bus in the Resource View.

Maestro Installation Guide

Maestro Software Setup

MAN-MASIG (Ver 1.33)

4-10

Advertising