KD Scientific Legato 130 Syringe Pump User’s Manual

Publication 5617-008 Rev D

Easy external connections to a computer or other

control devices are made through USB and Digital

I/O. Simple ASCII commands make communication

with the pump easy. For direct control of the pump,

the user can use the I/O interface (15pin Dsub). A

trigger output and a trigger input in for external

events such as a process parameter is met. The

footswitch input will allow the control of the pump

through an external device. The unit also has an

output for run indication allowing connection to a

remote light.

The Legato 130 offers complete flexibility with the

user able to use most manufacturer’s syringes with

sizes ranging from 0.5 ul to 1 ml.

The infuse/withdraw programmable Legato 130

offers maximum flexibility and capability for

configuring and running different programs. Up to 2

programs of 50 steps each can be configured and

stored in the unit, and recalled quickly with the touch

of a button. The programs are identified with a 15

character alphanumeric name for easy identification

and can be stored on the computer and downloaded

at future dates. A relative clock is available to start

and stop programs based on time. Extensive

programming options allow the user to duplicate

configurations, append one configuration to another,

rename programs, delete programs, export programs

to a PC or export a program to another pump. This

feature can ensure consistency and accuracy of

multiple pumps.

Preprogrammed profiles include Constant Rate and

Ramp. These standard profiles make configuration easy

to set up. If more complexity is needed the user can select

from advanced programming options including:

Time delays

Repeating steps

Stopping the pump

Triggering the pumps TTL output

Accepting an event input in such as a user

touch or motor stall

Events can trigger the pump to withdraw or infuse

The pump Information/setup screen shows the pump’s

software version, and lubrication intervals. The pump’s

alarm configurability includes alarms for near end of run

(user selectable), completion of run, power up, and

keypad clicks.

Pump Model

Legato 130

Single syringe infuse/withdraw with

program option for 2 programs, 50 steps each..