Run Mode Errors

ERROR 101-

Power to the pump was lost.

ERROR 102-

The A/D convertor is not working.

Set-up Errors

ERROR 201-

Backlight setting out of range, 10 to 100

ERROR 202-

Alarm setting out of range, 1 to 99

ERROR 203-

Force percentage out of range, 1 to 100.

ERROR 204-

Pump address out of range, 0 to 99.

ERROR 205-

Pump number out of range, 1 to 99.

ERROR 206-

Syringe volume out of range, 0.05 µl to

1000 ml.

ERROR 207-

Syringe diameter out of range, 0.1 mm to

99 mm.

ERROR 210-

Infuse Rate out of range.

ERROR 211-

Withdraw rate out of range.

ERROR 212-

Syringe diameter is out of range.

ERROR 213-

Target volume exceeds syringe volume.

ERROR 214-

Target time exceeds syringe volume.

ERROR 215-

Total volume exceeds syringe capacity.

ERROR 216-

Volume is less than the minimum value.

ERROR 217-

Motor has stalled.

ERROR 218-

Program needs a rate.

ERROR 219-

Program needs infuse and withdraw rates

and a target volume.

Program Errors

ERROR 301-

Delay time out of range, must be at least

0.20 seconds.

ERROR 302-

Number of steps must be between 2 and

500.

ERROR 306-

Download to remote pump incomplete.

ERROR 307-

Syringe size and flow rate not

compatible, cannot set motor speed.

ERROR 308-

File exists.

ERROR 310-

Not all fields have been set.

ERROR 311-

Rate is out of range.

ERROR 312-

Time is out of range.

ERROR 313-

Volume is out of range.

ERROR 314-

First rate is out of range.

ERROR 315-

Second rate is out of range.

ERROR 316-

First time is out of range.

ERROR 317-

Second time is out of range.

ERROR 318-

First volume is out of range.

ERROR 319-

Second volume is out of range.

ERROR 320-

The pulse count is 0.

ERROR 321-

Bad memory sector in step #%d. Step

was deleted.

ERROR 322-

Volume exceeds syringe capacity

in step #%d.

ERROR 323-

Incompatible rate vs. syringe size in step

#%d.

ERROR 324-

Repeat count is 0.

NOTE: Error and Alarm text are shown in a

yellow box whereas Notice, Confirm and

Verified are shown in a green box.

Run Mode Errors:

Error 1XX

Set-up Errors:

Error 2XX

Program Errors:

Error 3XX

Critical Errors:

Error 4XX

ERROR CODES