Function library "LenzeIo1000Drv"

Project planning concept

Minimum configuration

10

L

DMS 1.0 EN - 07/2011 - TD05

3.3

Minimum configuration

For implementing the I/O system, a minimum configuration must be carried out. It consists

of a parameterisation block

L_io1000ParPDO15

for parameterising the communication

relationships and a process data block

L_io1000Data15

for evaluation the input/output

information.

 The parameterisation block must be connected to the process data block as follows:

 The parameterisation block does not have to be executed in the same task as the

process data block. In this case, the outputs of the parameterisation block must be

connected to the inputs of the process data block.