Function library "lenzeio1000drv – Lenze Function library LenzeIO1000Drv User Manual

Page 33

Advertising
background image

DMS 1.0 EN - 07/2011 - TD05

L

33

Function library "LenzeIo1000Drv"

Function blocks

L_io1000ParCounterEPMS603 - Parameterise counter

byCnt0

InputFrequencyTrackB

BYTE

Counter 1: Input filter of digital input 5, "B1"/"direction"

2 100 kHz
3 60 kHz
4 30 kHz
6 10 kHz
7 5 kHz
8 2 kHz
9 1 kHz

byCnt0SignalSelection

BYTE

Counter 1: Signal evaluation

0 Counter deactivated

• The other parameter data for the counter are ignored.

1 Rotary transducer 1-fold (at A and B)
2 Rotary transducer 2-fold (at A and B)
3 Rotary transducer 4-fold (at A and B)
4 Direction (pulse at A and direction at B)

bCnt0InvertDirectionTrackB

BOOL

TRUE Counter 1: Invert counting direction track B

byCnt1

InputFrequencyTrackA

BYTE

Counter 2: Input filter of digital input 4, "A2"/"pulse"

2 100 kHz
3 60 kHz
4 30 kHz
6 10 kHz
7 5 kHz
8 2 kHz
9 1 kHz

byCnt1

InputFrequencyTrackB

BYTE

Counter 1: Input filter of digital input 8, "B2"/"direction"

2 100 kHz
3 60 kHz
4 30 kHz
6 10 kHz
7 5 kHz
8 2 kHz
9 1 kHz

byCnt1SignalSelection

BYTE

Counter 2: Signal evaluation

0 Counter deactivated

• The other parameter data for the counter are ignored.

1 Rotary transducer 1-fold (at A and B)
2 Rotary transducer 2-fold (at A and B)
3 Rotary transducer 4-fold (at A and B)
4 Direction (pulse at A and direction at B)

bCnt1InvertDirectionTrackB

BOOL

TRUE Counter 2: Invert counting direction track B

Identifier/data type

Information/possible settings

Advertising