Function library "LenzeIo1000Drv"

Function blocks

L_io1000Data610 - process data transfer PDO6 ... PDO10

58

L

DMS 1.0 EN - 07/2011 - TD05

4.14

L_io1000Data610 - process data transfer PDO6 ... PDO10

This FB coordinates the digital and analog input/output data of the process data objects

PDO6 ... PDO10. The FB is the interface between the PLC and the I/O system.

 Data from the PLC are transmitted to the I/O system (digital and analog output

channels) via the abyPDO6...10_DataToIO inputs.

 The statuses of the digital and analog input channels are transmitted to the PLC via the

abyPDO6...10_DataFromIO outputs.

Call possible in:

;

Cyclic task

…

Interrupt task

;

Time-controlled task (INTERVAL)

…

Event-controlled task (EVENT)

L_io1000Data610

⎯ bEnablePDOTransfer

dnState ⎯

⎯ abyPDO6_DataToIO

dnStatePDO6_DataToIO ⎯

⎯ abyPDO7_DataToIO

dnStatePDO7_DataToIO ⎯

⎯ abyPDO8_DataToIO

dnStatePDO8_DataToIO ⎯

⎯ abyPDO9_DataToIO

dnStatePDO9_DataToIO ⎯

⎯ abyPDO10_DataToIO

dnStatePDO10_DataToIO ⎯

⎯ bResetFail

dnStatePDO6_DataFromIO ⎯

⎯ DataFrom_IOParPDO610

dnStatePDO7_DataFromIO ⎯

⎯ DataFrom_IParComGuarding

dnStatePDO8_DataFromIO ⎯
dnStatePDO9_DataFromIO ⎯

dnStatePDO10_DataFromIO ⎯

bFail_DataToIO ⎯

bFail_DataFromIO ⎯

bFail_Module ⎯

abyPDO6_DataFromIO ⎯
abyPDO7_DataFromIO ⎯
abyPDO8_DataFromIO ⎯
abyPDO9_DataFromIO ⎯

abyPDO10_DataFromIO ⎯