Function library "LenzeIo1000Drv"

Function blocks

L_io1000ParCounterEPMS602 - Parameterise counter

byInputFrequencyTrackA

BYTE

Input filter of digital input 1 and 5, "A"/"pulse"

2 100 kHz
3 60 kHz
4 30 kHz
6 10 kHz
7 5 kHz
8 2 kHz
9 1 kHz

byInputFrequencyTrackB

BYTE

Input filter of digital input 4 and 8, "B"/"direction"

2 100 kHz
3 60 kHz
4 30 kHz
6 10 kHz
7 5 kHz
8 2 kHz
9 1 kHz

byInputFrequencyReset

BYTE

Input filter of digital input 6 and 7, "reset"

2 100 kHz
3 60 kHz
4 30 kHz
6 10 kHz
7 5 kHz
8 2 kHz
9 1 kHz

byAlarmFunction

BYTE

Process alarm

A process alarm can be triggered in case of the following events:

bits0 Reserved
bits1 Reserved

Bit 2 Counter limit overflow

bits3 Counter limit underflow
bits4 Comparison value reached

Bit 5 Final value reached
Bit 6 Reserved
Bit 7 Reserved

byCounterFunction

BYTE

Counting function

0 Continuous counting
1 Single counting, main counting direction is forward
2 Single counting, main counting direction is backward
3 Single counting, no main counting direction
4 Periodic counting, main counting direction is forward
5 Periodic counting, main counting direction is backward
6 Periodic counting, no main counting direction

Identifier/data type