Industrial PC | Parameter setting & configuration

Parameterisation using the L-force »Engineer«

Addressing structure in the »Engineer«

6.2

Addressing structure in the »Engineer«

In order to be able to address the individual components, the »Engineer« maps the

complete Industrial PC in a linear code range. Each parameter is listed in a code which can

either be changed or can only be read. The length of the code list depends on the

corresponding hardware assembly.

The basic IPC device uses the code range from 0 to 200;

The Ethernet on board interface uses the code range

from 220 to 260;

The optional panel uses the code range from 400 to 600;

The PLC (Motion/Logic) uses the code range from 600 to 800;

If optional extension modules are used, the code range is extended accordingly. Every

extension module is provided with the card and the interface parameters;

A card plugged into a slot is equipped with one or more interfaces. If a card is plugged

into a slot, the code range is extended accordingly:

The parameters of the extension modules use a maximum of 500 parameters each. The

code number range depends on the slot:
– Slot 1 uses codes 1000 to 1499,
– Slot 2 uses codes 1500 to 1999.